A dryer exhaust duct ending inside a crawl space instead of venting outside. A duct that ends in a crawl space can add lint and moisture to the space.
A dryer exhaust duct ending inside a crawl space instead of venting outside. A duct that ends in a crawl space can add lint and moisture to the space.
An electrical panel with insulation packed around the wiring and a nest built inside. Materials stored inside a panel can interfere with the breakers.
An electrical panel with insulation packed around the wiring and a nest built inside. Materials stored inside a panel can interfere with the breakers.
A crawl space pier built from a concrete block laid on its side with stacked shims on top. A pier arranged this way may not carry the floor load the way a solid pier would.
A crawl space pier built from a concrete block laid on its side with stacked shims on top. A pier arranged this way may not carry the floor load the way a solid pier would.
A moisture meter reading elevated levels at interior window trim. Elevated readings at a window can point to a possible water entry point.
A moisture meter reading elevated levels at interior window trim. Elevated readings at a window can point to a possible water entry point.
Fungal growth on the wood framing in a crawl space. Growth like this is usually associated with elevated moisture in the space.
Fungal growth on the wood framing in a crawl space. Growth like this is usually associated with elevated moisture in the space.
An inspector entering a low crawl space access to look at the foundation and framing. Access into tight spaces is part of a Hampton Roads home inspection.
An inspector entering a low crawl space access to look at the foundation and framing. Access into tight spaces is part of a Hampton Roads home inspection.
An exhaust duct ending in the attic instead of connecting to a roof or wall termination. Venting warm moist air into an attic can add moisture to the space.
An exhaust duct ending in the attic instead of connecting to a roof or wall termination. Venting warm moist air into an attic can add moisture to the space.
A split running along the grain of an attic roof truss member. A split of this size may reduce the strength of the member.
A split running along the grain of an attic roof truss member. A split of this size may reduce the strength of the member.
A termite mud tube running up a foundation wall. Termite inspections at Safe House are performed by our partner Pest Heroes.
A termite mud tube running up a foundation wall. Termite inspections at Safe House are performed by our partner Pest Heroes.
An open electrical junction box with exposed splices and no cover. Open splices in a box are a safety concern documented during a home inspection.
An open electrical junction box with exposed splices and no cover. Open splices in a box are a safety concern documented during a home inspection.
A level on a drain line showing it falls the wrong way. A drain line that does not fall toward its outlet may hold water.
A level on a drain line showing it falls the wrong way. A drain line that does not fall toward its outlet may hold water.
Roof shingles with heavy granule loss, cracking and curling along a rake edge. Shingles in this condition may be near the end of their service life.
Roof shingles with heavy granule loss, cracking and curling along a rake edge. Shingles in this condition may be near the end of their service life.
A receptacle tester showing an incorrect wiring condition at a wall outlet. Wiring conditions like this are documented during a home inspection.
A receptacle tester showing an incorrect wiring condition at a wall outlet. Wiring conditions like this are documented during a home inspection.
A door threshold with soft, deteriorated wood and peeling paint. Soft wood at a threshold may keep deteriorating where it stays wet.
A door threshold with soft, deteriorated wood and peeling paint. Soft wood at a threshold may keep deteriorating where it stays wet.
A panel interior with a screw that has pierced the panel wall near the main lugs, with arcing marks visible. Damage of this type is a safety concern noted during a home inspection.
A panel interior with a screw that has pierced the panel wall near the main lugs, with arcing marks visible. Damage of this type is a safety concern noted during a home inspection.
A prop mask left behind in an attic. One of the surprising finds from a Virginia Beach home inspection.
A prop mask left behind in an attic. One of the surprising finds from a Virginia Beach home inspection.
An attic floor with no insulation between the joists. Missing insulation can affect how well the home holds heat.
An attic floor with no insulation between the joists. Missing insulation can affect how well the home holds heat.
A tape measure showing about twelve inches of clearance under the floor framing in a crawl space. Limited clearance can make the space hard to access and inspect.
A tape measure showing about twelve inches of clearance under the floor framing in a crawl space. Limited clearance can make the space hard to access and inspect.
A screwdriver pushed into a floor joist showing soft, deteriorated wood. Soft framing members may not carry their intended load.
A screwdriver pushed into a floor joist showing soft, deteriorated wood. Soft framing members may not carry their intended load.
An inspector on the roof examining the shingle surface up close. Walking the roof is part of the roof portion of a Hampton Roads home inspection.
An inspector on the roof examining the shingle surface up close. Walking the roof is part of the roof portion of a Hampton Roads home inspection.
An inspector in protective coveralls on their back in a tight crawl space beside flexible ducts. Crawl space inspections are a routine part of a home inspection.
An inspector in protective coveralls on their back in a tight crawl space beside flexible ducts. Crawl space inspections are a routine part of a home inspection.
A water stain ring on an interior ceiling. A stain like this often marks a past or present water entry point.
A water stain ring on an interior ceiling. A stain like this often marks a past or present water entry point.
An inspector in a respirator coming out of a low crawl space hatch. Safe House inspects from the roof to the crawl space on every home inspection.
An inspector in a respirator coming out of a low crawl space hatch. Safe House inspects from the roof to the crawl space on every home inspection.
Exterior trim with soft, deteriorated wood, dark staining and flaking. Exterior wood in this condition may keep deteriorating.
Exterior trim with soft, deteriorated wood, dark staining and flaking. Exterior wood in this condition may keep deteriorating.
An exterior electric meter and panel partly covered by overgrown vegetation. Growth against a meter can restrict access to the equipment.
An exterior electric meter and panel partly covered by overgrown vegetation. Growth against a meter can restrict access to the equipment.
Two flexible exhaust ducts ending inside the attic. Ducts that end in an attic can release moisture into the space.
Two flexible exhaust ducts ending inside the attic. Ducts that end in an attic can release moisture into the space.
Fungal growth hanging from the underside of the subfloor in a crawl space. Growth like this is associated with high moisture in the crawl space.
Fungal growth hanging from the underside of the subfloor in a crawl space. Growth like this is associated with high moisture in the crawl space.
A flexible duct with torn insulation and a hole chewed through the outer cover. A damaged duct cover can reduce how well the system works.
A flexible duct with torn insulation and a hole chewed through the outer cover. A damaged duct cover can reduce how well the system works.
A floor joist supported by a stack of loose shims on a pier block. Loose stacked shims under a joist may allow movement in the floor above.
A floor joist supported by a stack of loose shims on a pier block. Loose stacked shims under a joist may allow movement in the floor above.
An inspector in protective gear working through a small closet floor hatch into the subfloor area. Tight access spaces are part of a thorough home inspection.
An inspector in protective gear working through a small closet floor hatch into the subfloor area. Tight access spaces are part of a thorough home inspection.
Fungal growth on the wood framing in a corner of a crawl space. Growth like this is associated with elevated moisture.
Fungal growth on the wood framing in a corner of a crawl space. Growth like this is associated with elevated moisture.
A sill plate on a foundation wall with soft, deteriorated wood and staining. A deteriorated sill plate may affect the framing it supports.
A sill plate on a foundation wall with soft, deteriorated wood and staining. A deteriorated sill plate may affect the framing it supports.
Roof shingles with granule loss, cracking and curled edges. Shingles in this condition may be near the end of their service life.
Roof shingles with granule loss, cracking and curled edges. Shingles in this condition may be near the end of their service life.
Mushrooms growing from the soil and the lower framing in a crawl space. Growth like this is associated with a damp crawl space.
Mushrooms growing from the soil and the lower framing in a crawl space. Growth like this is associated with a damp crawl space.
A plumbing pipe passing through an oversized, unsealed hole in the subfloor. An unsealed penetration can allow air and pests to move between spaces.
A plumbing pipe passing through an oversized, unsealed hole in the subfloor. An unsealed penetration can allow air and pests to move between spaces.
Termite mud tubes and wood damage on crawl space framing. Termite inspections at Safe House are performed by our partner Pest Heroes.
Termite mud tubes and wood damage on crawl space framing. Termite inspections at Safe House are performed by our partner Pest Heroes.
Blackened, deteriorated subfloor framing in a crawl space. Damage like this is associated with long term moisture in the space.
Blackened, deteriorated subfloor framing in a crawl space. Damage like this is associated with long term moisture in the space.
An electrical panel with dirt, dust and debris around the breakers. A panel interior in this condition is documented during a home inspection.
An electrical panel with dirt, dust and debris around the breakers. A panel interior in this condition is documented during a home inspection.
A water heater flue pipe touching a plastic water line. Clearance between a flue pipe and other materials is checked during a home inspection.
A water heater flue pipe touching a plastic water line. Clearance between a flue pipe and other materials is checked during a home inspection.
A moisture meter reading elevated levels at a window sill with peeling paint. Elevated readings at a sill can point to a possible water entry point.
A moisture meter reading elevated levels at a window sill with peeling paint. Elevated readings at a sill can point to a possible water entry point.
A thermal camera image of a ceiling showing a cold area below a bathroom. A cold area of this kind can indicate missing insulation or moisture.
A thermal camera image of a ceiling showing a cold area below a bathroom. A cold area of this kind can indicate missing insulation or moisture.
A rusted cast iron waste pipe with a long split along its length in a crawl space. A split pipe of this type may leak.
A rusted cast iron waste pipe with a long split along its length in a crawl space. A split pipe of this type may leak.
A screwdriver pushed through a metal pipe that has rusted through. A pipe rusted through may leak.
A screwdriver pushed through a metal pipe that has rusted through. A pipe rusted through may leak.
A thermal camera image of an interior wall showing a localized cold spot. A cold spot of this kind can indicate missing insulation or moisture.
A thermal camera image of an interior wall showing a localized cold spot. A cold spot of this kind can indicate missing insulation or moisture.
Irrigation pipes sealed with spray foam into a handmade plywood duct plenum. A non standard duct connection like this is documented during a home inspection.
Irrigation pipes sealed with spray foam into a handmade plywood duct plenum. A non standard duct connection like this is documented during a home inspection.